Can the chiller be linked with temperature and humidity control systems?
Yes. Aurashu air-cooled chillers can be seamlessly linked with temperature and humidity control systems to achieve precise, intelligent environmental regulation for various applications such as cleanrooms, data centers, industrial workshops, and comfort cooling environments.
The chillers support integration through standard communication protocols including Modbus, BACnet, and LonWorks, enabling direct connection to Building Management Systems (BMS) or Automatic Control Systems (ACS). This allows real-time monitoring and automatic adjustment of cooling capacity, supply air temperature, and humidity levels based on dynamic load conditions.
By connecting the chiller to humidity control modules, the system can automatically balance dehumidification or humidification according to ambient conditions—ensuring stable indoor environments even under fluctuating outdoor temperatures or seasonal changes.
Aurashu’s advanced microcomputer and PLC control technologies provide high-precision PID algorithms, allowing smooth and coordinated operation between the chiller, air handling units (AHU), and terminal fan coil units (FCU). The system can maintain ±0.5°C temperature accuracy and ±3% relative humidity deviation, meeting the demands of precision manufacturing, pharmaceutical production, and laboratory conditions.
Additionally, the integration improves energy efficiency, as the chiller’s compressor and fan speed can be adjusted intelligently according to real-time temperature and humidity needs, reducing unnecessary operation and saving energy.
Aurashu’s engineering team provides customized linkage solutions, including communication module setup, field commissioning, and remote system monitoring support, ensuring optimal performance and stability in complex control environments.
FAQs
- Integrated Water-Cooled Chiller | Compact Central HVAC Cooling Unit - FAQ
- Integrated Low-Temperature Heating Modular Unit | Integrated Air Source Heat Pump-FAQ
- Falling Film / Flooded Water-Cooled Chiller – FAQ
- Water-Cooled Centrifugal Chiller | High-Capacity HVAC Cooling System – FAQ
- Water-Cooled Screw Chiller | Central HVAC Cooling Solution – FAQ
- Screw Type Air-Cooled Chiller & Heat Pump Unit – FAQ
- Variable speed Scroll Air-CooledModular Units—FAQ
- Natural Cooling Air-Cooled Screw Chiller – FAQ
- Modular Air-Cooled Cold (Hot) Water Unit – FAQ
- Air-Cooled Chiller Unit – FAQ
- Air Filter FAQ
- Installation & After-sales
- Maintenance & Care
- Procurement & Order
- Product Performance & Advantages
- System Operation & Troubleshooting
- Technical Documents & Support
- Product Customization & Applications