Guest Comfort & Personalized Experience
Room temperature, humidity, air quality, and noise levels directly affect guest satisfaction and loyalty. Preferences vary widely, requiring flexible and rapid adjustment capabilities.
Room temperature, humidity, air quality, and noise levels directly affect guest satisfaction and loyalty. Preferences vary widely, requiring flexible and rapid adjustment capabilities.
Guest rooms and premium public spaces must maintain low noise levels (≤30–35dB). Equipment should be discreetly integrated or concealed to preserve the aesthetic appeal.
Different areas such as guest rooms, banquet halls, dining spaces, spas, swimming pools, and conference rooms each require unique conditions: Varying temperature, humidity, airflow, and air cleanliness standards; High-humidity zones (e.g., pools, spas) must prevent condensation and mold; Kitchens demand strong exhaust systems to remove odors.
Hotels operate year-round, with HVAC systems consuming 40%–60% of total energy. Seasonal changes and fluctuating guest flows mean that full-capacity operation often wastes energy.
In the post-pandemic era, guests pay greater attention to air cleanliness, fresh air volume, sterilization, and odor removal, significantly raising expectations for indoor air quality.
Decades of project expertise tailored for hotels and resorts.
Flexible solutions designed to match unique operational needs.
Certified products ensuring stable, long-term performance.
End-to-end service from design to installation and after-sales.
Guest rooms use fan coils/VRV/VRF for on-demand temperature control (±1°C). Public areas have central AC with VAV, auto-adjusting by guest count and usage.
Low-noise fans and silenced air ducts keep guest room noise ≤30dB; equipment is concealed in suspended ceilings and wall cabinets to match interior decor.
Banquet halls/conference rooms use overhead airflow with floor return for uniform air and quick adaptation to high-occupancy heat loads; kitchens have efficient exhaust/supply, dining areas use airflow isolation to stop odors; pools/spas use dedicated dehumidification heat pumps to keep humidity 50%-60% and prevent condensation/mold.
Intelligent building management auto-controls AC by occupancy; inverter tech + waste heat recovery save 20%-35% energy; free cooling cuts cooling use in suitable climates.
Fresh air units, HEPA filtration, and UV germicidal lamps/plasma purification filter PM2.5, bacteria, and viruses; fresh air volume is designed for ≥30 m³/h per person to ensure fresh, odor-free indoor air.
A highly efficient and energy-efficient water-source/ground-source heat pump combination and modular cooling/heating units adapt to different building needs.
A multi-effect heat recovery fresh air unit supports CO₂/VOC monitoring and adaptive fresh air control, improving indoor quality and energy efficiency.
A dedicated constant temperature and humidity air conditioning system precisely controls pool area air temperature and humidity, removes chlorine and odor, and optimizes evaporation and dehumidification.
A BMS building intelligence system supports regional temperature control, one-card control service, energy consumption monitoring, and centralized operation and maintenance.
Fan coil units and air handling units feature low-noise, high-static-pressure designs, balancing environmental performance and user experience.
Incorporating variable-frequency energy-saving modules, waste heat recovery modules, and regional temperature control optimizes overall system energy efficiency.