Passenger Comfort & Air Quality
High passenger density in enclosed carriages leads to heat buildup, CO₂ accumulation, and rising humidity. Ensuring stable temperature, fresh air supply, and low noise is critical for passenger satisfaction.


High passenger density in enclosed carriages leads to heat buildup, CO₂ accumulation, and rising humidity. Ensuring stable temperature, fresh air supply, and low noise is critical for passenger satisfaction.
High-speed operation causes rapid changes in temperature, humidity, and pressure. Systems must adapt to extreme outdoor climates (−30°C to 40°C, humid or dry) while maintaining cabin stability.

Tunnels and underground stations introduce high dust loads, which lower air quality and accelerate equipment wear. Effective filtration and purification systems are essential.
Any HVAC failure can compromise passenger comfort, disrupt train schedules, and even affect operational safety. High reliability and redundancy are mandatory.
Rail HVAC runs continuously for long hours, often across diverse climates and passenger loads. Energy consumption is high, making efficiency and smart control vital to reducing operating costs.

Decades of project experience in subways, high-speed rail, and airports, with proven system integration capability.

Tailored HVAC, ventilation, and fire smoke extraction systems designed to meet specific project challenges.

Products tested to Class A fire resistance, seismic standards, and noise control regulations for rail transit.

Comprehensive service from system design, installation, commissioning to long-term maintenance and upgrades.
Smart sensors and variable-frequency AC adjust cooling/heating in real time based on passenger flow and climate, ensuring comfort and efficiency.

Multi-stage filters (coarse, medium, HEPA) remove >95% dust/PM2.5; mixed fresh-return air saves energy. Corrosion-resistant ducts ensure durability.


Dual compressors, redundant fans, and remote monitoring guarantee uninterrupted operation and predictive maintenance.
Waste heat recovery and full heat exchangers reduce losses; BMS/PLC auto-controls cut energy use by 15%–30%.

Low-temp heat pumps work at −30°C; dehumidification and anti-corrosion exchangers ensure stability in hot, humid zones.
Customized central air conditioning and metro-specific fans provide reliable cooling and heating for carriages, stations, and tunnels, with optimized performance for high passenger density.
Multi-stage filtration (coarse, medium, HEPA) combined with intelligent air monitoring removes PM2.5, dust, and harmful particles, maintaining healthy indoor air.

Fire smoke exhaust fans, dampers, and composite ducts comply with Class A fire protection standards, ensuring rapid smoke extraction and emergency safety.


Seismic-resistant structures, anti-corrosion ducts, and redundant key equipment extend system service life and ensure stable operation under extreme environments.
Low-noise centrifugal fans and vibration-damping mounting keep system operation ≤65dB, reducing disturbance in carriages and concourses.
Heat recovery modules, inverter compressors, and smart load adjustment reduce annual energy consumption by 15%–30%, lowering operational costs.





